20 SC-CF & SC-MP Service Manual
Display Is Flashing
If digital thermometer water temperature reading is 112°F or higher and
keypad display indicates correct temperature, carry out the following
tests:
If display stops flashing after pressing a key, this means that a power failure has occurred.
System works fine.
To shorten filter cycle duration:
5 Press and hold
Light key for
5 seconds.
Display will
show a value
that represents the filter
cycle duration in hours.
Use Down
arrow key
to lower
the number
of hours.
0 = no filtration
12 = continuous filtration
When the
desired setting
is displayed,
press Light key
again. The filter
cycle will start
immediately.
6 If you do read 240 VAC,
replace Spa Pack.
3 Remove plastic cover. With a volt-
meter, read voltage between the
two heater wires on the board.
4 If you do not read 240 VAC, pump
may be overheating water during
filter cycle.
Shorten filter cycle duration.
If weather is very hot:
1 Remove spa cover (even during
the night). Start blower if spa is
equipped with one. Wait until
spa cools down (add cold water
if necessary).
If hot weather is not a factor:
2 Lower Set Point below current
water temperature.
The "Heater" indicator should
disappear from keypad display.