59SC-CF & SC-MP Service Manual
How To Replace The Spa Pack
When replacing a SC-CF or SC-MP spa pack, it is important to make
sure to turn power off before proceeding.
1• Unplug Pump 1, Pump 2 (or blower)
and ozonator connectors.
2• Remove 2 screws from front pack cover.
3• Lift the Spa Pack cover.