27SC-CF & SC-MP Service Manual
FLO Error Condition
4 If problem has not been solved,
lower Set Point at 60° by pressing
on Down arrow key and turning
pump off; then short two pres-
sure switch terminals with jumper
cable.
5 An FLC error condition should
occur.
FLC error condition identifies
pressure switch as source of
problem.
Try readjust pressure switch. If
this isn't possible, replace switch.
(Refer to "How to Adjust the
Pressure Switch" section of this
manual.)
6 If FLC error condition does not
occur, problem may be either
with switch cable or board.
Replace Spa Pack.