32 SC-CF & SC-MP Service Manual
Prr Error Condition
The Prr error condition indicates a problem with regulation sensor.
The system is constantly verifying if temperature probe reading is
within normal limits.
Note that water temperature must be over 35°F in order to carry out the following steps.
Press any key after each step to reset the system.
Power may remain On.
3 Reconnect probe.
If Prr error condition still persists,
replace probe with a spare and
place probe head directly in spa
water.
If problem is solved, replace
probe.
4 Replace Spa Pack if problem
persists.
1 Verify if regulation probe is
properly connected.
2 Disconnect probe connector
and clean probe connector pins.
Even a small coating of film may
cause a bad connection.
Probe
connector
pins
Note: Make sure to use the right
probe! MC-CF probe does not
work on a SC-CF or SC-MP spa pack.
Probe wires should be in this order:
Black
Green
Red
PIN #1
PIN #4