43SC-CF & SC-MP Service Manual
Spa Not Heating!
1 Remove plastic cover and measure
voltage between the two heater
screws on the board.
Replace board if you are not
getting a reading of 240 VAC.
If "Heater" indicator appears on the display, but spa is still not heating,
carry out the following tests to correct the problem:
2 If voltage reading is correct,
verify if heater nuts are
properly connected to the
element.
If not, tighten nuts to the
element.
3 If problem persists, replace
the element.
If "Heater" indicator lights up on the display: