63SC-CF & SC-MP Service Manual
How To Adjust The Pressure Switch
When a voltmeter is not available:
1 Turn Pump 1 off.
2 Decrease the pressure switch setting
to 0.5 P.S.I. or until three flashing dots
are displayed.
3 Start increasing pressure switch setting
by very slowly turning adjustment
screw clockwise until three flashing
dots disappear, then another full turn.
4 Turn pump on at low speed for 30
seconds; there should be no flashing
dots on display.
5 Turn pump off and wait 30 seconds.
You should not see the three flashing
dots.
6 If you see an error, restart the adjust-
ment procedure.
If you are not able to adjust the pres-
sure switch, change it.