OPERATING INSTRUCTIONS
29
compression pressure [mbar] 1100 1300
gas entry temperature
dry 200°C
vapour saturated 100 °C
V 1 – V 55 V 95 – V 430 / VG
speed
[
min
-1
]
50 Hz [60Hz]
2800 [3400] 1450 [1750]
service liquid
temperature 10 °C
60 °C
density 1200 kg/m
3
viscosity 4 mm
2
/s
overpressure for water pressure
test
3 bar
All pressures indicated in mbar are absolute pressures
All values are applicable for a service liquid temperature of 15 °C.