5.1 ZONE DEFINITIONS
As demonstrated in Figure 5-1, sections [001] to [016] represent zones 1 through 16 respectively, where the first
digit in each of these sections represents the zone's definition. To disable a zone, clear the contents of the section
corresponding to the desired zone by pressing the
[FORCE]
key 3 times and pressing
[ENTER]
. There are 6
available Zone Definitions, which are described as follows.
5.1.1 E
NTRY
D
ELAY
1
Sections [001] - [016] = Zones 1 - 16: First Digit = 1
When the system is armed and when a zone defined with Entry Delay 1 opens, the control panel will
generate an alarm after the programmed Entry Delay 1 Timer has elapsed. This is to provide users with
enough time to enter the protected area and disarm the system. To program the Entry Delay 1 Timer, key in
the desired 3-digit delay value (000-255 seconds, Default = 45 seconds) into section [069]. Entry Delay
zones are commonly used at the entry/exit points of the protected area (i.e. front/back door, garage, etc.).
Using different Entry Delays (see Entry Delay 2 below) is useful when, for example, one entry point
requires a longer delay than the other entry point, or in a partitioned system where each partition may
require a different Entry Delay. Also, refer to Zone Speed on page 25.
5.1.2 ENTRY DELAY 2
Sections [001] - [016] = Zones 1 - 16: First Digit = 2
Entry Delay 2 zones are identical to Entry Delay 1 zones (see section 5.1.1), except it uses a separate
Entry Delay Timer. To program the Entry Delay 2 Timer, key in the desired 3-digit delay value (000-255
seconds, Default = 45 seconds) into section [070]. Also, refer to Zone Speed on page 25.
Press the
[
ENTER
]
key
Key in
3-digit
[
SECTION
]
Zone Definition
First Digit
Zone Options
Feature Select
Enter the
[
INSTALLER
CODE
]
Zone Definitions
1 -
Entry Delay 1
2 -
Entry Delay 2
3
- Follow
4
- Instant
5 -
24Hr. Burglary
If zone 2 = Keyswitch Zone
If zone 3 = Fire Zone
6 -
24Hr. Buzzer
If zone 3 = Delayed Fire Zone
Zone Options
[1]
Auto Zone Shutdown Enabled
[2]
Bypass Enabled
[3]
Stay Zone
[4]
[5]
Zone Alarm Type
off off Audible Alarm (steady)
off on Audible Alarm (pulsed)
on off Silent Alarm
on on Generates only a report
[6]
Intellizone
[7]
Delay alarm transmission
[8]
Force Zone
Keyswitch Options
Only if Zone 2 = keyswitch zone
[1]
off = Maintained
on = Momentary
[2]
off = Regular Arm
on = Stay Arm
Select
one
Press
[
ENTER
]
[001]
= Zone 1
[009]
= Zone 90
[002]
= Zone 2
[010]
= Zone 10
[003]
= Zone 3
[011]
= Zone 11
[004]
= Zone 4
[012]
= Zone 12
[005]
= Zone 5
[013]
= Zone 13
[006]
= Zone 6
[014]
= Zone 14
[007]
= Zone 7
[015]
= Zone 15
[008]
= Zone 8
[016]
= Zone 16
Zone Partition
Assignment
Second Digit
Select
one
Zone Partition Assignment
1-
Zone Assigned to Partition 1
2-
Zone Assigned to Partition 2
Keypads beep twice
Figure 5-1: Spectra Zone Programming