SPECTRA SERIES 49
12.7 PGM FOLLOWS GLOBAL PGM (LIBERATOR)
Section [610]: General Options
Option [3] OFF = PGM1 on Liberator follows Global PGM Disabled (default)
Option [3] ON = PGM1 on Liberator follows Global PGM Enabled
Option [4] OFF = PGM2 on Liberator follows Global PGM Disabled (default)
Option [4] ON = PGM2 on Liberator follows Global PGM Enabled
Each PGM on the Liberator Wireless Bus Module can be programmed to follow the events and/or PGM Delay Timer
defined by the Global PGM. This means if the option is enabled, the Liberator’s PGM will ignore its activation and
de-activation events and timer. Instead it will follow the activation and de-activation events programmed in section
[124] and [125] and will follow the Global PGM Delay timer programmed in section [068]. For more information, refer
to pages 39 and 40.
12.8 SERIAL NUMBER DISPLAY (LIBERATOR)
Section [630]
This feature will display the serial number of any Liberator Motion Detector, Contact Switch or Remote Control on
any Spectra keypad. To do so:
1. Enter section [630]
2. If it is a Liberator Motion Detector or Contact Switch, press its tamper switch. If it is a Liberator Remote Control,
press any two buttons on the remote control. The keypads will emit a confirmation beep.
3.
LED Keypads:
The serial number digits will appear one at a time by illuminating the corresponding light. To view the next
digit press the
[
ENTER
]
key.
LCD Keypads:
Then entire serial number will appear on the screen.
4. Return to step 2 to continue or press
[CLEAR]
to exit the Serial Number Display.
After entering section [630], ignore the first reading as it will not be accurate.
12.9 SIGNAL STRENGTH DISPLAY (LIBERATOR)
Sections [631] to [638]
This feature allows you to determine whether the Liberator Module will effectively receive signals from specific wireless
motion detectors and contact switches. Please note that this feature will only work with wireless transmitters that have
already been assigned to an Expansion Input (zone) as described in Wireless Transmitter Assignment on page 47.
After entering the appropriate section as described below, the keypads will display the transmitters relative signal
strength. LED Keypads will illuminate numbers from 1 to 8. LCD keypads will display from 1 to 8 characters on the
LCD screen. A reading of 1 is the weakest and a reading of 8 is strongest. Although, an average reading of 3 and up is
acceptable. Sometimes moving the transmitter or receiver just a little bit will greatly increase the signal reception.
After entering the desired section, ignore the first reading as it will not be accurate.
Section [631] = Expansion Input 1 = Transmitter Assigned in section [601]
Section [632] = Expansion Input 2 = Transmitter Assigned in section [602]
Section [633] = Expansion Input 3 = Transmitter Assigned in section [603]
Section [634] = Expansion Input 4 = Transmitter Assigned in section [604]
Section [635] = Expansion Input 5 = Transmitter Assigned in section [605]
Section [636] = Expansion Input 6 = Transmitter Assigned in section [606]
Section [637] = Expansion Input 7 = Transmitter Assigned in section [607]
Section [638] = Expansion Input 8 = Transmitter Assigned in section [608]
12.10 RESET LIBERATOR MODULE
Section [640]
After entering section [640] and pressing
[ENTER]
, the control panel will reset sections [601] to [623] to default values.