4
R
EFERENCE
& I
NSTALLATION
M
ANUAL
PART 1: INTRODUCTION
1.1 FEATURES
• Up to 16 fully programmable zones:
1725EX: 4 zones [8 zones with ATZ (1725 only)] + 2 keypad zones, can expand to 16 zones
1728EX or 1758EX:5 zones [10 zones with ATZ (1728/1758 only)] + 2 keypad zones, can expand to 16 zones
• Up to 8 remote controls built-in with 1758 and 1758EX only.
• Two completely independent partitions. Many of the features and options in the Spectra System can be inde-
pendently set for each partition such as event reporting, entry/exit delay, auto-arming and many more. All zones,
the keyswitch and all user codes are assigned to specific partitions, making this a true partitioned system.
• Communication bus facilitates the addition, programming and monitoring of wireless and/or hardwire expansion modules.
• 1 Installer Code and 48 User Codes (including: 1 System Master, 2 Masters, and 1 Duress)
• One or more fully programmable outputs (PGMs).
• Simple, direct and logical programming
• Event Call Direction: The Spectra Series Control Panel events are divided into 5 groups of events. Each of these
event groups can be programmed with a separate dialing sequence.
• Two 32-digit Central Station Telephone Numbers and one 32-digit Back-up Telephone Number
• Contact ID, Pager Format and many more High-Speed Communication Formats
• "False Alarm Prevention" features such as: Intellizone, Auto Zone Shutdown, Beep on Exit Delay, Programmable
Delay Before Alarm Transmission, and Recent Closing Report
• Regular Arming, Stay Arming, Instant Arming, Force Arming, One-Touch Arming, Auto-Arming, or Arming with
Keyswitch
• 256 Event Buffer with time stamp
• Optional 5A Alarm Relay (1758 and 1758EX only)
• Telephone Line Supervision
• Keypad activated panic alarms
• Compatible with Winload software for Windows®
• And much, much, more…
1.2 SPECIFICATIONS
1.2.1 SPECTRA CONTROL PANEL
• AC Power: 16VAC transformer with minimum 20VA rating (Rec.: 40VA), 50-60Hz
(UL tested to 60Hz only)
• Battery: 12VDC, 4Ah
• Aux. Power: 600mA typical, 700mA maximum, fuseless shutdown @ 1.1A
• Bell Output: 1A, fuseless shutdown @ 3A (1725/EX and 1728/EX) or 2.5A (1758/EX)
• PGM1 Output: 150mA
• PGM2 Output: 2.5A (1758/EX only)
1.2.2 SPC-319 L
IBERATOR
W
IRELESS
M
ODULE
• Power input: 9-16VDC
• Current Consumption:70mA
• Frequency Hopping: @ 902MHz - 928MHz or 868MHz
• Range of Detectors & Contact Switches: 1000m (3280’) or 300m (984’) for 868 MHz
Range of Remote Controls: 30m (100‘)
• Data Rate:10 KB/s
• Sensitivity:-105dBm
• Dimensions (without antenna): 15cm H x 16cm L x 3cm W (6”H x 6.5”L x 1.1”W)
• Operating Temperature: 0°C to 50°C (32°F to 122°F)
• Operating Humidity: 85%
• PGM Outputs:1 + 1(optional)
• PGM Output current: 5A relay
1.2.3 HAND-HELD REMOTE CONTROLS
• Water Resistant
• Range: 30m (100ft.)
• Battery: Lithium 3V (CR2032)