SPECTRA SERIES 33
8.2.4 SPECIAL DISARMING REPORT CODES
Section [186]
Whenever using one of the special disarming features, the control can send the report code to the central
station, identifying how the system was disarmed.
__/__
CANCEL AUTO-ARM
: A partition is disarmed during the Timed Auto-Arm's 60-second exit delay (see
page 26). Only if Disarming Reporting Options (see page 38) are set to always report disarming.
__/__
REMOTE DISARM
: System disarmed using the Winload software
__/__
KEYSWITCH DISARMING
: System disarmed using a keyswitch (see page 22).
8.2.5 Z
ONE
A
LARM
R
EPORT
C
ODES
Sections [187] - [190]
A report code can be programmed for each of the 16 available zones. Whenever a zone generates an
alarm, the control panel can send the appropriate report code to the central station, identifying which zone
generated an alarm.
8.2.6 Z
ONE
A
LARM
R
ESTORE
R
EPORT
C
ODES
Sections [191] - [194]
A report code can be programmed for each of the 16 available zones. The control panel can transmit these
report codes to the central station identifying which zone was restored.
A zone is restored when it closes after generating an alarm or once the bell has cut-off after alarm
generation. Please refer to Zone Restore Report Options on page 38.
8.2.7 SPECIAL ALARM REPORT CODES
Sections [195] - [196]
Whenever the system generates an alarm due to one of the conditions listed below, the control panel can
send the appropriate report code to the central station, identifying the type of alarm.
__/__
EMERGENCY PANIC
: Panic keys [1] & [3] have been pressed (see page 30).
__/__
AUXILIARY PANIC
: Panic keys [4] & [6] have been pressed (see page 30).
__/__
FIRE PANIC
: Panic keys [7] & [9] have been pressed (see page 30).
__/__
RECENT CLOSING
: After arming the system, an alarm is generated within period defined by the
Recent Close Delay (see page 37).
__/__
AUTO ZONE SHUTDOWN
: A zone communicates more than the programmed number of
transmissions in a single armed period (see page 23).
__/__
DURESS
: A Duress access code is keyed in (see page 19).
8.2.8 ZONE TAMPER REPORT CODES
Section [197] - [200]
A report code can be programmed for each of the 16 available zones. Whenever a tamper or wire fault
occurs on a zone, the control panel can send the appropriate report code to the central station, identifying
which zone was tampered.
8.2.9 Z
ONE
T
AMPER
R
ESTORE
R
EPORT
C
ODES
Sections [201] - [204]
A report code can be programmed for each of the 16 available zones. Whenever a tampered zone is
restored, the control panel can send the appropriate report code to the central station, identifying which
zone has been restored.
If Tamper Recognition (see page 29) is disabled, the control panel will not report the occurrence of
any tampers, wire faults or tamper restores.