Spectra 1728/EX & 1738/EX - 29 - Programming Guide
APPENDIX A - ADEMCO CID REPORT CODE LIST (PROG.)
If using the Ademco Contact ID Programmable code format, enter the 2-digit hexadecimal value from the table below (Prog.
Value ) into sections [160] to [213] to program the desired report codes. To enter a 0 value press the [FORCE] key.
CID# Reporting Prog.
Code Value
CID# Reporting Prog.
Code Value
CID# Reporting Prog.
Code Value
MEDICAL ALARMS - 100 2 04 Low W ater Le vel 2 F 4 03 Aut omatic O/ C 5 D
100 Medical Alarm 01 205 Pump Activat ed 30 404 Lat e t o O/ C 5E
101 Pendant Transmitter 02 2 06 Pump Fa ilure 31 405 De ferred 5 F
102 Fail to Report In 03 SYSTEM TROUBLE S - 3 00 & 310 406 Cancel 60
FI RE A LARM S - 11 0 300 System Trou ble 32 407 Re mote Ar m/ Disarm 61
110 Fire Alarm 04 301 AC Lo ss 33 408 Quick Arm 62
111 Smoke 05 3 02 Low System B attery 34 409 Keyswitch O/C 63
112 Combustion 06 303 RAM Checksum Bad 35 REMOTE ACCESS - 410
113 Water Flow 07 304 ROM Checksum Bad 36 411 Callback Request Made 64
114 Heat 08 305 System Reset 37 412 Success - Download Access 65
115 Pull Station 09 306 Panel Program Changed 38 413 Unsuccessful Access 66
11 6 Duct 0A 3 07 Self-Test Failure 39 414 System S hu tdown 67
11 7 Flame 0B 3 08 System S hu tdo wn 3A 4 15 Diale r Shu tdo wn 68
11 8 Nea r Alar m 0C 3 09 Bat tery Test Failure 3B ACCESS CONTROL - 420
PANIC ALARMS - 120 3 10 Ground Fa ult 3 C 4 21 Access De nied 69
120 Panic Alarm 0D SOUNDER/RELAY TROUBLES - 320 422 Access Report By User 6A
1 21 Duress 0E 3 20 Sou nd er Relay 3D
122 Silent 0F 321 Bell 1 3E SOUNDER RELAY DISABLES - 520
123 Audible 10 322 Bell 2 3F 520 Sounder/Relay Disabled 6B
BURGLAR ALARMS - 130 323 Alarm Relay 40 521 Bell 1 Disable 6C
1 30 Burg lary 11 324 Tr ou ble Relay 41 522 Bell 2 Disable 6D
1 31 Perim et er 12 3 25 Re versing 42 523 Alar m Relay Disab le 6E
132 Interior 13
SYSTEM P ERIPHERAL TROUBLES - 330 & 3 40
524 Trouble Relay Disable 6F
1 33 24 - Ho ur 14 330 System P eriphe ral 43 525 Re versing Re lay Disab le 70
1 34 Entry/Exit 15 3 31 Polling Lo op Ope n 44
1 35 Day/Night 16 3 32 Polling Lo op Sh ort 45 COMMUNICATION DISABLES - 550 & 560
1 36 Ou tdo or 17 3 33 Exp. Mo du le Failure 46 5 51 Diale r Disa bled 71
1 37 Tamp er 18 334 Re pe ater Fa ilure 47 5 52 Ra dio xmitte r Disa bled 72
1 38 Near Alarm 19 3 35 Loca l Printe r Pap er Out 48 BYPASSE S - 570
GENERAL ALARMS - 140 3 36 Loca l Printe r Fa ilu re 49 5 70 Zo ne Bypass 73
140 General Alarm 1A COMMUNICATION TROUBLES - 350 & 360 5 71 Fir e B ypa ss 74
141 Polling Loop Open 1B 350 Communication 4A 572 24-Hour Zone Bypass 75
1 42 Polling Loop Short 1C 3 51 Te lco Fault 1 4B 5 73 Burg. Bypa ss 76
143 Expansion Module Failure 1D 352 Telco Fault 2 4C 574 Group Bypass 77
1 44 Sensor Tamper 1E 3 53 Lon g Range Ra dio 4 D TEST/MISC. - 600
145 Expansion Module Tamper 1F 354 Fail to Communicate 4E 601 Manual Trigger Test 78
24-HOUR NON-BURGLARY - 150 & 160 3 55 Loss of Radio Sup ervisio n 4 F 6 02 Per iod ic Test Re po rt 79
150 24-Hour Non-Burglary 20 356 Loss of Central Polling 50 603 Periodic RF Xmission 7A
151 Gas Detected 21 PROTE CTION LOOP TROUBLES - 370 6 04 Fir e Te st 7B
1 52 Refrige ration 22 370 Prote ction Lo op 51 6 05 St atu s Report to Follow 7C
153 Loss of Heat 23 371 Protection Loop Open 52 606 Listen-in to Follow 7D
1 54 Wa ter L ea kage 24 3 72 Pro te ction Lo op sho rt 53 607 Walk Te st Mode 7E
1 55 Foil Bre ak 25 3 73 Fire Trou ble 54 6 21 Even t Log Reset 7 F
1 56 Day Trou ble 26 SENS OR TROUBLES - 3 80 622 Event Log 50% Full 80
1 57 Lo w Bo ttled Gas Level 27 380 Sen sor Tro ub le 55 6 23 Even t Log 90% Full 81
1 58 High Temp 28 381 Loss of Sup er. -RF 56 624 Even t Log Over flow 82
1 59 Lo w Tem p 29 382 Loss of Sup er. - RP M 57 625 Time/Dat e Re set 83
1 61 Lo ss o f Air Flow 2A 3 83 Sensor Tamper 58 626 Time/Dat e I naccu rate 84
FI RE SUPE RV ISORY - 2 00 & 21 0 3 84 RF xmtr. Lo w Ba ttery 59 627 Program Mod e Ent ry 85
200 Fire Supervisory 2B OPEN/CLOSE - 400 6 28 Pro gram Mode Exit 86
201 Low Water Pressure 2C 400 Open/Close 5A 631 Exception Schedule Change 87
202 Low CO2 2D 401 O/C by User 5B
2 03 Ga te Va lve S enso r 2E 4 02 Group O/C 5 C