Spectra 1728/EX & 1738/EX - 6 - Programming Guide
SYSTEM TIMERS
* Maximum 60 seconds for UL listed systems.
** 5 minutes minimum for ULC installations.
Section # Decimal Value (000 t o 255) Descriptio n D ef ault
[050]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 1)
600 msec.
[051]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 2)
600 msec.
[052]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 3)
600 msec.
[053]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 4)
600 msec.
[054]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 5)
600 msec.
[055]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 6)
600 msec.
[056]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 7)
600 msec.
[057]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 8)
600 msec.
[058]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 9)
600 msec.
[059]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 10)
600 msec.
[060]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 11 )
600 msec.
[061]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 12)
600 msec.
[062]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 13)
600 msec.
[063]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 14)
600 msec.
[064]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 15)
600 msec.
[065]
___/___/___ x 10 m sec.
ZONE SPEED (ZONE 16)
600 msec.
NOTE
: If ATZ is enabled (section [132] option [5]), do not set the Zone Speed to less than
50msec. as this may cause false alarms.
[066]
___/___/___ seconds (000 = fol low D eacti vatio n Even t) PGM1 TIMER 5 sec.
[067]
___/___/___ seconds (000 = fol low D eacti vatio n Even t) PGM2 TIMER 5 sec.
[068]
___/___/___ seconds (000 = fol low D eacti vatio n Even t) GLOBAL PGM TIMER 5 sec.
[069]
___/___/___ seconds ENTRY DELAY 1 45 sec.
[070]
___/___/___ seconds ENTRY DELAY 2 45 sec.
[071]
___/___/___ seconds EX IT DELAY 1* 30 sec.
[072]
___/___/___ seconds EX IT DELAY 2* 30 sec.
[073]
___/___/___ minutes ( 000 = no be ll on al ar m) BE LL CUT-OFF TI ME R (PARTITION 1) ** 4 min.
[074]
___/___/___ minutes ( 000 = no be ll on al ar m) BE LL CUT-OFF TI ME R (PARTITION 2) ** 4 min.
[075]
___/___/___ x 15 minutes (000 = disabled) NO MO VEMENT TIMER (PARTITION 1) Disabled
[076]
___/___/___ x 15 minutes (000 = disabled) NO MO VEMENT TIMER (PARTITION 2) Disabled
[077]
___/___/___ seconds (mi nim um 10 sec.) ANSW ERING MACHINE OVERRIDE DELAY Disabled
[078]
___/___/___ (000 = no answer, maximum = 15 rings) NUMBER OF RINGS 8 rings
[079]
___/___/___ x 2 sec. (mini mum 32 sec.) TLM FAIL TIMER 32 sec.
[080]
___/___/___ seconds DELAY ALARM TRANSMIS SION Disabled
[081]
___/___/___ (000 = 16, maximum = 16) M AXIM UM DIALING ATTEMPTS 8 attempts
[082]
___/___/___ seconds DELAY BE TW EE N ATTEMPTS 20 sec.
[083]
___/___/___ seconds PAG ER DE LAY 5 sec.
[084]
___/___/___ seconds (mi nim um 10 sec.) IN TEL LIZON E DELAY 48 sec.
[085]
___/___/___ seconds RECENT CL OSI NG DELAY No delay
[086]
___/___/___ minutes POW ER FAILURE REPORT DE LAY 15 min.
[087]
___/___/___ days (000 = disabled) AUTO TEST REPORT Disabled
[088]
___/___/___ 000 to 127 = +1 to +127 seconds
128 to 255 = -1 to -127 seconds
CLOCK ADJUST Disabled
[089]
___/___/___ (000 = disabled, maximum = 15) AUTO ZONE SHUTDO WN CO UN T ER 5
[090]
___/___/___ minutes ( 000 = di sabled) RECYCLE ALARM DELAY Disabled
[091]
___/___/___ (000 = disabled) RECYCLE ALARM COUNTER Disabled
[092]
___/___/___ attem pts before lo cking (000 = disab led) KE YPAD LO CK OU T Disabled
[093]
___/___/___ minutes ( 000 = di sabled) KE YPAD LO CK OUT DELAY Disabled
[094]
___/___/___ seconds (000 = disabled) PANIC LO CK OU T TIMER Disabled
[110]
___/___ : ___/___ hours (00 to 23) : minutes (00 to 59)
___/___ : ___/___ hours (00 to 23) : minutes (00 to 59)
___/___ : ___/___ hours (00 to 23) : minutes (00 to 59)
AUTO TEST REPORT (TI ME OF DAY) Disabled
[111]
AUTO-ARM TIME (PA RTITION 1) Disabled
[112]
AUTO-ARM TIME (PA RTITION 2) Disabled