Spectra 1728/EX & 1738/EX - 4 - Programming Guide
CONFIGURING T HE 1686H, 1686V and 1689 KEYPADS (Prior to V2.0)
The keypads zone numb er an d EOL definition are de fi ned through the ju mper s located on the PC B board. The jumpers are
as fol low s:
J1 - Keypad Zone Select Jumper (Zone Programming” on page 4)
Jum per J1 determines w hether the keypads zone i s Keypad Zo n e 1 or Keypad Zone 2. W hen the ju mper is OFF, the
keypads zone is Keypad Zone 2. When the jumper is ON, the keypads zone is Keypad Zone 1.
J1 OFF - Keypad Zone 2
J1 ON - Keypad Zone 1
J2 - EOL Definition Jumper
Jumper J2 determines the keypad zones EOL definition. When the jumper is OFF, EOL is disabled and the keypad zone
uses the on-board EOL resistor. When the jumper is ON, EOL is enabled and the keypad zone requires that an external EOL
resistor be connected (refer to Spectra 1728EX and 1728 PCB Layout” on page 38 and Spectra 1738EX and 1738 PCB
Layout” on page 39 for more details) .
J2 OFF - EOL disabled
J2 ON - EOL enabled
ZONE PROGRAMMING
When programming zones, the zone assignments are dependent on where the detection devices in the system are
connected. Do not assign inputs from different modules to the same expansion input. In 1728/EX control panel
installations that require using mostly the expansion inputs, refer to Reassign Zones to Expansion Inputs (see section [126]
option [8]).
Zone Recognition Table
Device
connected to
which input?
1728/EX 1728 1728/EX 1728
With Re-assign Keypad
Zone 2 enabled (see
page 10)
1738/EX 1738 1738/EX 1738
With Re-assign Keypad
Zone 2 enabled (see
page 10)
NO ATZ WITH ATZ NO ATZ WITH ATZ NO ATZ WITH ATZ NO ATZ WITH ATZ
Control Panel
Input 1 = Zone 1 Zone 1 & 6 Zone 1 Zone 1 & 6 Zone 1 Zone 1 & 8 Zone 1 Zone 1 & 8
Input 2 = Zone 2 Zone 2 & 7 Zone 2 Zone 2 & 7 Zone 2 Zone 2 & 9 Zone 2 Zone 2 & 9
Input 3 = Zone 3 Zone 3 & 8 Zone 3 Zone 3 & 8 Zone 3 Zone 3 & 10 Zone 3 Zone 3 & 10
Input 4 = Zone 4 Zone 4 & 9 Zone 4 Zone 4 & 9 Zone 4 Zone 4 & 11 Zone 4 Zone 4 & 11
Input 5 = Zone 5 Zone 5 & 10 Zone 5 Zone 5 & 10 Zone 5 Zone 5 & 12 Zone 5 Zone 5 & 12
Input 6 = N/A N/A N/A N/A Zone 6 Zone 6 & 13 Zone 6 Zone 6 & 13
Input 7 = N/A N/A N/A N/A Zone 7 Zone 7 & 14 Zone 7 Zone 7 & 14
Keypad
Zone 1 = Zone 6 Zone 11 Zone 6 Zone 11 Zone 8 Zone 15 Zone 8 Zone 15
Zone 2 = Zone 7 Zone 12 N/A N/A Zone 9 Zone 16 N/A N/A
Expansion
Input 1 = Zone 8 Zone 13 Zone 7 Zone 12 Zone 10 N/A Zone 9 Zone 16
Input 2 = Zone 9 Zone 14 Zone 8 Zone 13 Zone 11 N/A Zone 10 N/A
Input 3 = Zone 10 Zone 15 Zone 9 Zone 14 Zone 12 N/A Zone 11 N/A
Input 4 = Zone 11 Zone 16 Zone 10 Zone 15 Zone 13 N/A Zone 12 N/A
Input 5 = Zone 12 N/A Zone 11 Zone 16 Zone 14 N/A Zone 13 N/A
Input 6 = Zone 13 N/A Zone 12 N/A Zone 15 N/A Zone 14 N/A
Input 7 = Zone 14 N/A Zone 13 N/A Zone 16 N/A Zone 15 N/A
Input 8 = Zone 15 N/A Zone 14 N/A N/A N/A Zone 16 N/A