EasyManua.ls Logo

Spectra 1738 - Programmable Output (PGM) Configuration; PGM Activation and Deactivation Events; PGM Event Group and Sub-Group Codes

Default Icon
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spectra 1728/EX & 1738/EX - 7 - Programming Guide
PROGRAMMABLE OUTPUTS
Each PGM Deactivation event can be used as another start (activation) event if their respective PGM timer (see sections
[066] to [068]) is programmed with a value other than 000.
Example: section [120] = 05 03 02: this means PGM1 will activate whenever partition 2 is Stay Armed.
Section #
Event Group # Sub-Group # Partition #
[120]
PGM 1 PGM Activatio n Even t ___/___ ___/___ ___/___
[121]
PGM 1 PGM Deactivation Event __ _/___ __ _/___ ___/___
[122]
PGM 2 PGM Activation Event ___/___ ___/___ ___/___
[123]
PGM 2 PGM Deactivati on Event __ _/___ __ _/___ ___/___
[124]
Global PGM Activation Event ___/___ ___/___ ___/___
[125]
Global PGM Deactivation Event
U sed to activate PGMs on
expansion modules & LCD keypads.
___/___ ___/___ ___/___
Event Group # Su b-Group #
00 = Zone OK 01 to 16 = Zones 1 to 16
99 = Any Zone
01 = Zone Open 01 to 16 = Zones 1 to 16
99 = Any Zone
02 = P art it io n Sta tus 00 = System not ready (Partition 1 only)
01 = System ready (Partition 1 only)
02 = Steady Alarm in Partition
03 = Pulsed Alarm in Partition
04 = Pulsed or Steady Alarm in Partition
05 = Alarm in Partition Restored
06 = Bell Squawk Activated (Partition 1 only)
07 = Bell Squawk Deactivated (Partition 1 only)
08 = Ground start (Partition 1 only)
09 = Disarm Partition
10 = Arm Partition
11 = Entry Delay (breach when system is armed)
99 = Any Sub-Group
05 = Non-Reportab le Events 00 = Telephone Line Trouble (Partition 1 only)
01 = [PG] or [FNC1] key was pressed (Partition 1 only).This
option can also be used to reset smoke detectors.
02 = Instant Arming
03 = Stay Arming
04 = For ce Armi ng
05 = Fast Exit (Force & Regular Only)
06 = PC Fail to Communicate (Partition 1 only)
07 = Midnight (Partition 1 only)
99 = Any Sub-Group (Partition 1 only, except 02 to 05 )
06 = Arm/Disarm with Remote Control 01 to 08 = Remote Controls 1 to 8
99 = Any Remote Control
07 = Button Pressed on Remote
(see button option ā€œBā€ on page 24)
01 to 08 = Remote Controls 1 to 8
99 = Any Remote Control
08 = Button Pressed on Remote
(see button option ā€œCā€ on page 24)
01 to 08 = Remote Controls 1 to 8
99 = Any Remote Control

Related product manuals