Not a substitute for official published procedural guide
Detailed instructions/videos located at support.spectralogic.com
Replacement robotics
#1 Phillips screwdriver
USB flash drive (FAT32)
o For collecting Auto-support Log File (ASL)
Discontinue
Verify robotic movement has halted
Verify with customer that move requests from host have been halted
support.spectralogic.com has a downloadable video of this procedure under
“Service Partner Resources.” A portal account is required
It is recommended that all tapes are removed from drives by customer before
procedure to avoid potential stuck tapes after power-up
Verify customer has a current backup of the following (if applicable):
o Library configuration
o MLM and DLM databases
o Encryption keys
Refer to the “Spectra T50e Robotics Replacement Instructions” service guide
for a list of information that should be documented/backed-up by customer
prior to service
If you attempt to remove magazines without depressing magazine release
buttons, internal magazine latches may break. This type of failure cannot be
repaired in the field and the library must be returned to Spectra Logic