Ensure you select the correct option (Robotics) upon reboot of library.
Selecting the wrong option (Controller) at the prompt results in library option
keys being erased and will require manual re-entry of all keys
Fully loaded magazines can weigh several pounds and tapes can fall out of the
magazine when the magazine is out of the library. Handle carefully to avoid
damaging media or magazines
Replace removed magazines back into their original locations to prevent
possible inventory corruption
1. Power off library and disconnect power cables
2. Remove left/right magazines
If you attempt to remove magazines without depressing the magazine release
buttons, the internal magazine latches may break. This cannot be repaired in
the field, the library must be returned to Spectra Logic
3. Loosen screws securing front panel, then tilt front panel towards you
Note routing of front panel ribbon cable under two retention tabs
4. Disengage ZIF connector and remove front panel ribbon cable
Cable should require little/no force to remove. If not, ZIF connector is not
disengaged on both sides
ZIF connector is easily damaged and not field replaceable. If damaged, a new
front panel must be ordered
5. Carefully pull robotics to front of library to access robotics ribbon cable
Do not remove robotics from library at this time
6. Disconnect robotics ribbon cable
Remove plastic clip securing cable to circuit board
o Note orientation of clip. It must be replaced in the same orientation
Grasp ribbon cable and pull upward to remove from connector
7. Hold both ribbon cables down to keep them out of the way, then pull robotics out
of library
8. Move gear rail in chassis slightly to the left to facilitate installation of replacement
robotics