EasyManua.ls Logo

Spellman ST SERIES - Page 87

Spellman ST SERIES
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
101501-565 Rev C Page 56 of 58
6.6.18 Program Local/Remote Mode
Description:
The host requests the firmware to switch between Local and Remote
Mode.
Direction:
Host to supply
Syntax:
<STX><99><,><ARG><,><CSUM><ETX>
Where:
<ARG> 1 = Remote, 0 = Local in ASCII format
Response:
If an error is detected, the Power Supply responds with:
<STX>99,!,<ERROR>,<CSUM><ETX>
Please reference the Error Code section for a list of valid error codes.
If the message is accepted, the Power Supply responds with:
<STX>99,$,<CSUM><ETX>

Table of Contents