Spengler LeECG Series - User Manual

Spengler LeECG Series
226 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
CARDIOMATE EVI 7 & 10
Modèle : Séries LeECG et
NeoECG
Électrocardiographe
Manuel de l’utilisateur

Table of Contents

Questions and Answers

  • E
    Erika CookAug 14, 2025
    Why does my Spengler LeECG Medical Equipment show AC interference?
    • G
      Gabriel RodgersAug 14, 2025
      AC interference on your Spengler Medical Equipment, presenting as a 50Hz sine wave overlap with amplitude and jitter on the ECG baseline, can stem from several factors. Ensure the device and patient bed are properly grounded. Verify correct electrode and leadwire connections, and sufficient conductive paste application. Avoid patient contact with conductive objects and nearby powerful electrical equipment. Confirm the patient isn't wearing metal ornaments and the AC filter frequency is correctly set. If issues persist, utilize an AC filter, noting it may slightly attenuate the recorded waveform.
  • J
    Joshua StanleyAug 18, 2025
    What to do if my Spengler Medical Equipment displays baseline drift?
    • T
      Tami MillerAug 18, 2025
      If your Spengler Medical Equipment shows baseline drift (irregular up and down movement of the printed ECG baseline), check that the electrodes are firmly attached and the lead wires are properly connected. Ensure the electrodes and the patient's skin are clean, and that enough conductive paste is applied. Also, consider whether the patient moved or breathed during recording, and avoid mixing old and new electrodes. If the problem persists, use an ADS filter.
  • C
    Christopher MackAug 21, 2025
    What to do if Spengler LeECG Medical Equipment displays 'XX lead off'?
    • T
      Terri Young PhDAug 21, 2025
      If your Spengler Medical Equipment displays 'XX lead off' (all leads off), follow these steps: 1. Check the electrodes and lead wires, re-applying electrodes or reconnecting wires if needed. 2. Ensure the patient cable is properly connected to the device. 3. If waveforms are still absent, assess if the device is inoperable due to amplifier overload or saturation.
  • G
    gsmithAug 25, 2025
    Why is the ECG waveform out of the grid area on my Spengler Medical Equipment?
    • K
      Keith BrooksAug 25, 2025
      The ECG waveform may be out of the grid area on the printing paper of your Spengler Medical Equipment due to great fluctuation of the waveform. Set the sensitivity to "Auto". The device will automatically adjust the sensitivity according to the amplitude of the ECG signal.
  • L
    leslieyoungAug 27, 2025
    What to do if Spengler Medical Equipment says 'Low battery!'?
    • H
      hollandkathleenAug 27, 2025
      If your Spengler Medical Equipment displays 'Low battery!', charge the battery immediately.
  • C
    curtisbarbaraAug 31, 2025
    What to do if my Spengler LeECG Medical Equipment says 'Battery depleted. Power off soon.'?
    • J
      joel78Aug 31, 2025
      If your Spengler Medical Equipment displays 'Battery depleted. Power off soon.', connect the DC power supply or use the recorder base to power the device, or charge the battery immediately.
  • W
    wellspatriciaSep 3, 2025
    How to fix Spengler Medical Equipment when some lead without waveform printout?
    • L
      Lori DavisSep 3, 2025
      If you acquire ECG data immediately after applying leadwires to the patient with your Spengler Medical Equipment, the ECG traces may not display because the ADS is not stable yet. Wait for the waveform of each lead to stabilize with good contact before ECG measurement.
  • L
    Lori MeyersSep 6, 2025
    What to do if Spengler LeECG Medical Equipment export failed?
    • L
      Lisa HarrisSep 6, 2025
      If the export fails on your Spengler Medical Equipment, check the USB device and try exporting the data again.
  • C
    Christina DavidsonSep 9, 2025
    What to do if Spengler Medical Equipment says 'Insufficient memory space'?
    • J
      Jesse KingSep 10, 2025
      If your Spengler Medical Equipment indicates 'Insufficient memory space', delete unwanted historical files or change the storage device/location.

Summary

Safety Guidance

Device Warnings

Crucial safety instructions for device usage, installation, and operation.

Defibrillator and Pacemaker Warnings

Specific safety advice for use with cardiac devices like defibrillators.

Battery Warnings

Safety precautions for battery handling, charging, and disposal.

Operational Cautions

General Cautions

Important precautions for device operation, environment, and handling.

Cleaning & Disinfection Cautions

Safety notes for cleaning and disinfecting the device and accessories.

Product Introduction

Intended Use

Specifies the medical purpose and qualified user requirements.

Device Functionality

Function Features

Lists key capabilities and functionalities of the ECG device.

Operating Modes

Describes different operational modes: Routine, Emergency, Standby, Demo.

Operation Preparations and Setup

Unpacking and Checking

Steps for inspecting the device and accessories upon arrival.

Preparing the Device

Detailed steps for setting up the device and recorder base.

Preparing the Patient

Instructions for patient preparation for ECG acquisition.

Attaching Electrodes

Guidance on proper placement of electrodes on the patient.

Screen Introduction

Main Screen Overview

Description of the primary display during ECG acquisition.

Entering Patient Information

Acquisition, Analysis, and Printing

Selecting Working Mode

Choosing the appropriate measurement mode for ECG acquisition.

Selecting Lead Mode

Configuring the number of ECG leads to acquire.

Acquisition and Analysis

Process of capturing ECG data and performing analysis.

File Management

System Settings

ECG Setup

Configuration for sampling modes, leads, rhythm, and filters.

Troubleshooting

Prompt Messages and Solutions

Table of common messages and their corresponding solutions.

AC Interference

Identifying and resolving AC signal interference on ECG traces.

EMG Interference

Identifying and resolving EMG signal interference on ECG traces.

Cleaning and Maintenance

Accessories

Technical Specifications

Spengler LeECG Series Specifications

General IconGeneral
CategoryMedical Equipment
TypeElectrocardiograph (ECG)
Power SourceAC power and rechargeable battery
PrintingThermal printer
MemoryInternal memory for ECG data storage (capacity varies by model)
ConnectivityUSB, Wi-Fi
CompatibilityCompatible with standard ECG electrodes and paper