Step 4: Clean espresso brewer
Slide red locking latch fully to left to
unlock brewer. Disconnect water inlet
tube’s quick-connect tting.
Lift brewer up approx. 2-3cm to
clear drive assembly and remove it
from dispenser.
Grip brewer at top and pull forward
and down so it hinges down/outwards
approx. 20°/3cm.
Rotate espresso outlet so tube points
away from centre of brewer to align
retaining nib to release position, then
pull it away to release it.
SERVICE TASKS
Wash all parts under running water
and scrub away any dried coffee
residue with brushes. Dry after
cleaning. Set aside.
Slide cake pusher off back of brewer
to separate it and fully unlock the
brewer cover from the brewer (A).
Then pull brewer cover out fully to
separate it from brewer (B).
Pull brewer cover up/away from
centre of brewer until it extends by
2-3cm.
A
B
Important:
For Annual and Biannual
Services rebuild the brewer
with PN10037204. Dispose of
all used parts in the appropriate
recycling bins. Refer to “Install
espresso brewer service kit” for
instuctions.