CL & PSL50 Series
TROUBLESHOOTING
Error Code on Display Potential Cause Recommended Solution
EAB_2 Dispenser arm jammed during movement Check movement
EDC_01...15
Motor running time exceeded. Container fails to achieve set
dosage (in gr).
Recalibrate container
EDB_01...15
Motor current exceeding the limit value. Req.EMK-pnts
could not be reached in max. allowed time.
Check container opening
Replace product
EDF_01...15 Motor has jammed 3 times (sluggish)
Check mixer
Perform run test
EE_08 Brewer-1 movement error
Replace brewer and/or drive
Close door correctly
EE_13 Brewer motor-2 not present
Check electrical connections
Replace brewer drive
EE_18 Brewer-2 movement error
Replace brewer and/or drive
Close door correctly
EEA_01 Error while closing, sieve head blocked
Check brewer movement.
Rinse toothed wheels of brewer
Check brewer assembly
Close door correctly
EEA_02 Exact closed position not reached
Check sieve head & filter
Clean sieve head and brewer