CL & PSL50 Series
SERVICE TASKS
Step 10: Replace fast mixer motor assembly (annually & biannually)
Disconnect canister panel via two
screws at front. Rotate it up/back.
Using a long, straight screwdriver,
release the two clips securing mixer
motor assembly to housing. Then push
mixer motor back about 1/2cm and
pull it down to release it. Disconnect
cable and tube connectors. Replace
fast mixer motor assembly with new.
Reassemble in reverse order.
02
01
WARNING:
When working with electrical
components, always turn the
dispenser OFF at the main switch
and/or disconnect the plug from
the outlet to prevent risk of
electrical shock.