EasyManuals Logo

SPEX 270M User Manual

Default Icon
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
270M
Rapid Scanning Imaging Spectrograph
warranty services
The Original Spex Sales Order number
is
helpful
to
know
Your Customer Account Number, if known,
is
also helpful
Any special instructions
14.2 Removing returnable components from your Instrument:
Turn off the power switch and disconned the power cord and other cables from the
instrument.
14.2.1 Removing a Grating:
Refer to the Optical Components: Changing Gratings sedion and follow the
instrudions until the point where the grating or turret is removed. Then cover the
grating using only the grating cover that was shipped with the instrument. To prepare
a cover, apply a strip
of
vinyl eledrical tape along each side, leaving a 1/2"
(1
cm) flap
extending beyond each side. Exercise extreme caution to avoid contading the grating
surface. Tilt the cover so that the bottom edge slips under the grating first, then gently
rotate the top of the cover until the grating is fully covered. While holding it
in
place,
secure it by sticking the tape flaps to the sides of the grating mount. Do the same for
each grating
to
be returned.
14.2.2 Removing a Circuit Board:
To remove a Circuit board form the 270M, open the top cover and open the wire
harness retainers
to
provide slack
in
the wiring. Disconned the wiring from the boards,
noting the
connedor
numbers for future reference. Push the wiring aside as you lift
out the baffle from between the circuit boards and the mirror mounts. From the
outside of the rear wall remove the screws holding the board spacers and lift the
board(s) out of the instrument, disconneding and noting
connedor
locations for the
cables as you go. Pack the board(s)
in
an antistatic bag for return
to
the fadory.
14.3 Packing the 270M:
To prepare your 270M for shipment, it is important
to
restrain the side entrance and
exit mirrors, if your instrument is so equipped. If the side mirrors are not rotated
to
the
side walls, turn on the power, and they should automatically
retrad
to
the walls.
Wrt:h
care
to
avoid contading the mirror surface, secure the mirror assemblies
to
the side
walls with nylon cable ties or an equivalent. There are attachments provided on the
baffles for this purpose.
Revillec:I
November
24,
1992
49