Mains DC Power Supply
Electrical power for the pump diodes must be provided by an external DC power supply.
Power for the internal electronics must be provided by a DC auxiliary power supply.
SPI Lasers recommends the following DC power supplies for the pump diode supply
Customer sourced Power Supply
Customer must follow Supplier instruction Manual for Parallel Operation if more than one power supply to be used.
Must conform to the specifications in the following slide for EOL (End Of Life) Current and Voltage.
TDK Lambda GEN 50-200-3P400
Aux 24V PSU(0.5A Rated) 24 ±5% Isolating
MEAN WELL RST-10000-48
May require additional Capacitive Support for first few
milliseconds of operation. See Figure below.