IM-P192-02 MI Issue 214
Fig. 8
Horizontal flow limited to 7 bar g (101 psi g)
and saturated steam applications only
Fig. 7
Vertical flow limited
to 7 bar g (101 psi g)
and saturated steam
applications only
Flow
Flow
Flow
3.2 Mechanical installation
Warning: Do not alter the adjustment nut at the back of the TVA flowmeter shaft, as
this will affect the flowmeters calibration.
Orientation
The TVA owmeter can be installed in any orientation when used on saturated steam
applications and when the pressure is below 7 bar g (101 psi g), see Figures 7, 8 and 9.
When the pressure is above 7 bar g (101 psi g) or used on a superheated steam application
the TVA owmeter must be installed in a horizontal pipe, with the electronics housing below
the body, see Figure 9.
Note: The TVA owmeter operates with ow in one direction only. It is not intended for use
with bi-directional ow. The TVA owmeter is clearly marked with a direction of ow arrow.
Caution: If the electronic housing is
mounted at an angle of 45° (or more) from
the vertically downward position the PMO
(maximum operating pressure) must be
limited to 7 bar g (101 psi g) and saturated
steam applications only.
The electronic housing must be mounted
vertically downward for all superheated
applications.