Date of issue: March 2016 Revision 2 Page 38/80
- Switch off the cooling system by pushing
power button B.
- Activate cleaning mode pushing the
corresponding button C.
- Use a common product suitable for sanitising
stainless steel, plastic and rubber objects (such
as AMUCHINA® in Italy).
IMPORTANT:
Carefully follow the instructions of the
product used with regard to timing and
method of conservation.
- Remove the cover from the upper tank.
!ATTENTION!
Since the freeze mode has just been
deactivated, the cylinder is under pressure,
for this reason i twill be necessary to relief
it from pressure before starting the
cleaning operations.
- Relief the cylinder pressure by slowly moving
the tap handle until the pressure is completely
discharged (fig. 18).
- Remove the fixing bracket from the pump
pressure pipe (fig.19).
- Disconnect the pressure pipe from the pump
by rotating it of 90° counter-clockwise and then
from the freezing cylinder connection pipe, by
pulling it upward (figure 20 and 21).