EasyManua.ls Logo

SPM U-go - LEDs for ON Button and Consistency Level 3 Flash; LED for Consistency Level 1 Flashes; LEDs for ON and WASH Buttons Flash; Product Level LED Flashes

SPM U-go
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ausgabedatum: März 2016 Revision: 2 Seite: 51/80
Problem Possible cause Solution
The LEDs for the ON
button and consistency
level 3 flash
Motor blocked
Tank probe detached
Tank probe short-circuit
Product consistency too high, turn off,
wait 30 minutes and turn on again with a
lower consistency level
Reconnect probe
Replace probe
The LED for consistency
level 1 flashes
Tank probe detached
Temperature inside the tank is too
high
Reconnect probe
Turn off the appliance and wait a few
minutes for the temperature of the
system, which has been raised by
washing with hot water, to decrease
The LEDs for the ON
button and the WASH
button flash
Tank probe short-circuit Replace probe
The product level LED
flashes
Mix temperature too low The amount of mix in the freezing
cylinder is too small, top up the top tank
or open mix flow tube
The number 3
consistency level LED is
blinking
Product temperature too high
Temperature probe disconnected
Remove the product and cool it down
until ambient temperature, then re-
introduce
Check the probe and re-connect

Table of Contents