Ausgabedatum: März 2016 Revision: 2 Seite: 51/80
Problem Possible cause Solution
The LEDs for the ON
button and consistency
level 3 flash
• Motor blocked
• Tank probe detached
• Tank probe short-circuit
• Product consistency too high, turn off,
wait 30 minutes and turn on again with a
lower consistency level
• Reconnect probe
Replace probe
The LED for consistency
level 1 flashes
• Tank probe detached
• Temperature inside the tank is too
high
• Reconnect probe
• Turn off the appliance and wait a few
minutes for the temperature of the
system, which has been raised by
washing with hot water, to decrease
The LEDs for the ON
button and the WASH
button flash
• Tank probe short-circuit • Replace probe
The product level LED
flashes
• Mix temperature too low • The amount of mix in the freezing
cylinder is too small, top up the top tank
or open mix flow tube
The number 3
consistency level LED is
blinking
• Product temperature too high
• Temperature probe disconnected
• Remove the product and cool it down
until ambient temperature, then re-
introduce
Check the probe and re-connect