11
Settings
Default settings
Below is a summary of the main instrument settings and their respective factory default values:
ISO standard = OFF (no condition evaluation will take place)
ISO 10816 default settings = PART 3, GROUP 1, SUPPORT Rigid
ISO 2372 default settings = CLASS 1, RPM 1500
Vibration quantity = VEL (velocity)
Amplitude units = Velocity rms and Peak
Units = Metric, Hz, vibration amplitude in g turned off
Averaging turned off
Number of lines = 200
External transducer = 10 mV/m/s2, settling time 3.0 seconds
Display contrast = Max
Dim time = 20
System of measurement and units
Available settings include the metric or imperial sys-
tem; frequency in Hz (Herz, cycles per second) or CPM
(cycles per minute - similar to RPM); and acceleration
in g or m/s2.
To make your settings:
1. Go to the Main display (A).
2. Use the arrow keys to navigate to the General Set-
tings icon (B), then press ENTER.
3. In the General settings display, select the Units icon
(C) and press ENTER.
4. In the Units display (D), use the UP/DOWN arrow
keys to highlight a checkbox (Metric (millimeters) or
Imperial (inch); Hz or CPM; and g). For each selec-
tion, press ENTER to mark your choice.
5. To save the settings, use the DOWN arrow key to
highlight the SAVE checkbox and press ENTER.
To return to the Main display, press the BACK key.
A
Main display
B
General settings
C
Units