APV DA4
DOUBLE SEAT MIX PROOF VALVE
FORM NO.: H337927 REVISION: UK-1
READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT.
INSTRUCTION MANUAL

Questions and Answers

  • S
    Sean LeachAug 3, 2025
    How to fix leakage at the upper housing flange of SPX FLOW APV DA4 Control Unit?
    • T
      Terrence WelchAug 4, 2025
      If there's leakage at the upper housing flange of your SPX FLOW Control Unit, consider replacing the upper housing seal (12).
  • A
    Andrea CantuAug 9, 2025
    What to do if there is leakage from the leakage bore between the connecting ports in SPX FLOW APV DA4 Control Unit?
    • D
      Diana StewartAug 9, 2025
      If you observe leakage from the leakage bore between the connecting ports in your SPX FLOW Control Unit, the issue may be with the lower housing seal (12) or the seat seals (11).
  • J
    jonesevanAug 15, 2025
    Why is there leakage from the yoke of my SPX FLOW Control Unit?
    • M
      Monique RoweAug 16, 2025
      If your SPX FLOW Control Unit is leaking from the yoke, the upper shaft seal (13, 14) or the seal of flushing chamber (15) may need replacement.
  • B
    boonecurtisAug 20, 2025
    How to resolve leakage at the outside of the lower valve shaft in SPX FLOW APV DA4?
    • B
      Bridget AdamsAug 20, 2025
      To address leakage on the outside of the lower valve shaft of your SPX FLOW Control Unit (after removing the spray connection), replace the lower shaft seal (13, 14).
  • B
    burnettnicoleAug 27, 2025
    What causes leakage from the inside of the lower valve shaft of SPX FLOW APV DA4 Control Unit?
    • W
      Wanda SmithAug 27, 2025
      If you notice leakage from the inside of the lower valve shaft in your SPX FLOW Control Unit, it might be due to the seat seals (11) or the upper shaft seal (13, 14).

Summary

Safety

Safety Instructions

Lists critical safety directives and warnings for safe operation and maintenance.

Intended Use

Mode of Operation

Valve in closed position

Details the valve's state and function when closed, separating liquids.

Valve in open position

Explains the valve's operation and connection when in the open state.

Cleaning

Cleaning recommendation

Provides a table with recommended cleaning steps, cycles, and quantities.

Installation and Commissioning

Welding Instructions

Crucial guidelines for welding the valve housing into the pipeline safely.

Technical Data

Maintenance

Service Instructions

Removal from the line system

Step-by-step instructions for safely disconnecting and removing the valve from the pipeline.

Removal of product-wetted parts

Detailed procedure for disassembling the valve and removing internal components.

Installation of seals and valve assembly

Step-by-step guide for fitting seals and reassembling the valve components correctly.

Installation of the valve insert

Instructions for inserting the valve assembly into the housing and connecting pneumatic lines.

Maintenance of Actuator

Assembly Instructions and Tools for Seals

Trouble Shooting

SPX FLOW APV DA4 Specifications

General IconGeneral
TypeControl Unit
Output Voltage24 VDC
Current Rating4 A
Weight1.5 kg
ModelDA4
ManufacturerSPX FLOW
Operating Temperature0°C to 50°C
Storage Temperature-20°C to 70°C

Related product manuals