EasyManua.ls Logo

SPX HANKISON HIT 75 - Electrical Schematics

SPX HANKISON HIT 75
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
Models 20 thru 75 - All Voltages
Only Models 50 and 75 - 230-1-50/60
ELECTRICAL SCHEMATICS
3
LINE
SW
G
1
2
3
3
4
A
TEMPERATURE
FPS
8
FM
CONDENSER
FANMOTOR
4
RC
HTS
7
5
M
LT
R
C S
6
REFRIGERANT
COMPRESSOR
4
4
HIGH
4
WIRING SCHEMATIC
2
3 1
OLT
14
Only Models 50 and 75 - 115-1-50/60
3
LINE
SW
G
1
2
3
3
4
A
TEMPERATURE
FPS
8
FM
CONDENSER
FANMOTOR
4
RC
HTS
7
5
M
LT
R
C S
6
REFRIGERANT
COMPRESSOR
4
4
HIGH
4
WIRING SCHEMATIC
Models 100 and 125 - All Voltages
FPS
TB
HTS
FM
OLT
LT
SW
M
Front of Dryer
(Outside)
Right Side of Dryer
(Inside)
COMPONENT LOCATIONS
RC
Models 20 thru 125 - All Voltages
LT
SW
FPS
CT
HTS
FM
OLT
M
RC
Front of Dryer
(Outside)
Right Side of Dryer
(Inside)
COMPONENT LOCATIONS
LEGEND
SW - On/Off Switch
OLT - Thermal Overload
M - Compressor Motor
RC - Run Capacitor
HTS - High Temperature Switch
LT - Fault Light
FPS - Fan Pressure Switch
FM - Fan Motor
TB - Terminal Block
CT - Contactor w/115V Coil
Only Models 50 and 75 - 115-1-50/60
SPX HANKISON HIT 75 - Electrical Schematics