EasyManua.ls Logo

SPX RADIODETECTION RD8200SG - Locator Settings and Survey Measurements

SPX RADIODETECTION RD8200SG
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2023 Radiodetection Ltd 28
5.8 Locator settings and
survey measurements
Check locator settings and send Survey
Measurements
The settings on the RD8200SG locator should
be correct, but it is worth checking the
following settings:
1. Ensure your paired device is switched on and
running a compatible app, for Android.
2. Check SMLOG COM is ON: SMLOG > COM >
ON.
3. Check SMLOG PROT is set to ASCII 2: SMLOG
> PROT > ASCII > 2.
4. Check GPS is ON: SMLOG > PROT > ASCII >
GPS+ > YES.
5. Check RTK is ON: GPS > RTK > ON.
6. Check MAG_H is ON: INFO > MAG-H > ON.
7. Press the Survey key to store and send Survey
Measurement to external device.
Erasing Survey Measurements
RD8200SG locator allows you to delete all
Survey Measurements. Erasing the log will
wipe the RD8200SG memory but is usually
recommended when you begin a new survey.
NOTE: Erasing Survey Measurements cannot be
undone.
Set DATA to DEL: SMLOG > DATA > DEL > YES.