Introduction Waukesha Cherry-Burrell
®
Brand C-Series Pump
01/2019 95-03008-IEC Page 9
Introduction
This manual contains installation, operation, cleaning, repair
instructions, and parts lists for the C-Series Centrifugal Pumps. It
also provides a troubleshooting chart to help in determining and
correcting possible pump problems.
Operating Parameters
Capacity: 10 to 780 gpm
Viscosity:
1 to 1500 cPs
Maximum operating
temperature: 212°F (100°C)
Maximum inlet pressure:
25 psi (1,7 bar)
Operating Speeds: 50
Hz: up to 2950 RPM
60Hz: up to 3500 RPM
Casing, backplate, and impeller are 316 stainless steel with pol-
ished sanitary finish.
• Port Connection: ISO 2852 fitting
s are standard.
• Power: Supplied by a standard IEC frame, C-frame design
mo
tor, through 45 kW.
• Seal Type “D”: Seal material is carbon rotating on stationary
st
ainless steel backplate.
• Seal Type “DG”: Gland ring with replaceable seal seat. See
page 72.
• Seal Type “E”: Water-cooled balanced double seal (carbon).
See page 73.
• Seal Type "F": "D" seal with
a water cascade attachment.
See item 137 on the parts list pages starting on page 56.
• Sanitary Polish: 32 Ra finish