Days value start to flash at this time
000 refers current days
Press the +/- key to set the number of days
001 refers to value of previous day
Long press the setting key for 3 seconds, and save current days
At this time, press +/- key again to view other log contents of set days
3.8 Parameter Setting Interface
Under this menu, the user can view and set system parameters. Setting shall be performed under guidance of
professional personnel; otherwise, setting error may cause system problems. See table 3-8 For parameter
setting contents
Parameter Setting Contrast Table
No. Displaying Items Notes Parameter Scope Default
Paremeters
1 TYPE OF BAT Battery Type User/flooded/Sealed/Gel Sealed
2 CAP OF BAT Battery Capacity 100
3000AH 200AH
3 VOLT OF SYS System Voltage 12V/24V/36V/48V/AUT
O
AUTO
4 OVR VOL DISC Overvoltage
Voltage
9.0
17.0V 16.0V
5 CHG LMT VOL Charging Limit
Voltage
9.0
17.0V 15.5V
6 EQUALIZ CHG Equalizing
charging Voltage
9.0
17.0V 15.2V
7 BOOST CHG Boost charging 9.0
17.0V 14.4V