EasyManuals Logo

Srne ML Series User Manual

Srne ML Series
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
4.3Abnormality Display and Alarm
No. Error Display Remarks LED Indication Buzzer Alarm
1 PV REV Photovoltaic Modules
Inversed Connection
ERROR indicator
steady on
Buzzer keeps alarming
2 PV OVP Photovoltaic Modules
Overvoltage
ERROR indicator
steady on
Buzzer keeps alarming
3 PV_MPP_OVP Over Set Vmp Voltage ERROR indicator
steady on
Buzzer Alarm for
1Min
4 PV OVER CRT Photovoltaic Modules
Overload
ERROR indicator
steady on
Buzzer Alarm for
1Min
5 OVER VOLTAGE System Overvoltage BAT Indicator fast
flash
ERROR indicator
steady on
Buzzer keeps alarming
6 LOAD SHORT CRT Load Short Circuit LOAD Indicator fast
flash
ERROR indicator
steady on
Buzzer Alarm for
1Min
7 LOAD OVER CRT Overload LOAD Indicator fast
flash
ERROR indicator
steady on
Buzzer Alarm for
1Min
9 OVER TMP BAT Environment
Temperature Over-
Temperature
ERROR indicator
steady on
Buzzer Alarm for
1Min
11 OVER TMP MOS Solar Charge
Controller Internal
Over-Temperature
ERROR indicator
steady on
Buzzer Alarm for
1Min
12 OVER DISCHARGE Battery Over-
Discharge
BAT Indicator slow
flash
ERROR indicator
steady on
Buzzer Alarm for
1Min
13 BAT UND VOL
WARN
Battery Under-Voltage ERROR indicator
steady on
Buzzer Alarm for 15
seconds
5. Product Specification Parameter
5.1 Electrical Parameter
Parameter Name Parameter Value
Model
ML2440/ML2440-LI ML4830/ML4830-LI
System Voltage
12V/24VAuto 12V/24V/36V/48V Auto