1
Pentair Water Pool and Spa
®
PUMP WARNINGS AND SAFETY INSTRUCTIONS
SUCTION ENTRAPMENT HAZARD: STAY OFF THE MAIN DRAIN AND AWAY FROM ALL SUCTION
OUTLETS!
Warnings and safety instructions for Pentair Water Pool and Spa® pumps and other related products are
available at: http://www.pentairpool.com/pool-owner/safety-warnings/ Call (800) 831-7133 for additional
free copies of these instructions. Please refer to www.pentairpool.com for more information related to
Pentair Water Pool and Spa® pumps.
For Pool and Spa Pumps (Non SVRS Pumps)
(Pentair Water Pool and Spa
®
, Sta-Rite
®
, and Pentair Pool Products
®
)
FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESULT IN SERIOUS BODILY
INJURY OR DEATH. THIS PUMP SHOULD BE INSTALLED AND SERVICED ONLY BY A QUALIFIED POOL
SERVICE PROFESSIONAL. INSTALLERS, POOL OPERATORS AND OWNERS MUST READ THESE
WARNINGS AND ALL INSTRUCTIONS IN THE OWNER'S MANUAL BEFORE USING THIS PUMP. THESE
WARNINGS AND THE OWNER'S MANUAL MUST BE LEFT WITH THE POOL OWNER.
F
THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A STRONG VACUUM AT THE
MAIN DRAIN AT THE BOTTOM OF YOUR POOL AND SPA. THIS SUCTION IS SO STRONG THAT IT CAN
TRAP ADULTS OR CHILDREN UNDER WATER IF THEY COME IN CLOSE PROXIMITY TO A POOL OR
SPA DRAIN OR A LOOSE OR BROKEN DRAIN COVER OR GRATE.
THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE POOL OR SPA WHEN COVERS ARE MISSING,
CRACKED OR BROKEN CAN RESULT IN BODY OR LIMB ENTRAPMENT, HAIR ENTANGLEMENT, BODY ENTRAP-
MENT, EVISCERATION AND/OR DEATH.
The suction at a pool or spa drain or outlet can cause:
Limb Entrapment: When a limb is sucked or inserted into an opening resulting in a mechanical bind or swelling. This
hazard is present when a drain cover is missing, broken, loose, cracked or not properly secured.
Hair Entanglement: When the hair tangles or knots in the drain cover, trapping the swimmer underwater. This hazard is
present when the flow rating of the cover is too small for the pump or pumps.
Body Entrapment: When a portion of the body is held against the drain cover trapping the swimmer underwater. This
hazard is present when the drain cover is missing, broken or the cover flow rating is not high enough for the pump or
pumps.
Evisceration/Disembowelment: When a person sits on an open pool (particularly a child wading pool) or spa outlet and
suction is applied directly to the intestines, causing severe intestinal damage. This hazard is present when the drain cover
is missing, loose, cracked, or not properly secured.
Mechanical Entrapment: When jewelry, swimsuit, hair decorations, finger, toe or knuckle is caught in an opening of an
outlet or drain cover. This hazard is present when the drain cover is missing, broken, loose, cracked, or not properly
secured.
NOTE: ALL SUCTION PLUMBING MUST BE INSTALLED IN ACCORDANCE WITH THE LATEST NATIONAL AND LOCAL
CODES FOR SWIMMING POOLS, SPAS AND HOT TUBS, INCLUDING NSPI STANDARDS AND CPSC GUIDELINES.
P/N 356476 Rev A (08-13-10)
READ AND KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
© 2010 Pentair Water Pool and Spa, Inc. All rights reserved - Sta-Rite® , Pentair Pool Products® and Pentair Water Pool and Spa® is a registered
trademark of Pentair Water Pool and Spa, Inc. Technical Support: (800) 831-7133
*356476*

Questions and Answers:

STA-RITE Supermax Specifications

General IconGeneral
Voltage115/230V
Seal TypeMechanical
Port Size2 inches
PhaseSingle
Inlet/Outlet Size2 inches

Summary

Section 1: Introduction

SuperMax® High Performance Pump Overview

Provides an overview of the SuperMax® High Performance Pump's design and suitability for various pool applications.

General Features

Lists the key characteristics and advantages of the SuperMax® pump, such as quiet operation and unionized fittings.

Section 2: Electrical Requirements

Electrical Requirements and Wiring

Details the necessary electrical specifications and warnings for safe installation and operation of the pump.

Wiring Installation

Provides step-by-step instructions for correctly wiring the SuperMax® pump, including wire size charts.

Section 3: Maintenance

The Pump Strainer Basket

Explains the function and importance of the pump strainer basket and the need for regular inspection.

Cleaning the Pump Strainer Basket

Outlines the procedure for safely cleaning the pump strainer basket, including necessary precautions.

Winterizing

Provides instructions on how to prepare the pump for winter to prevent freeze damage and maintain its condition.

Care of Electric Motor

Offers guidance on protecting the pump's electric motor from heat, dirt, and moisture to ensure longevity.

Section 4: Servicing

Pump Disassembly

Details the steps and tools required to safely disassemble the SuperMax® pump for servicing or repair.

Pump Reassembly/Seal Replacement

Explains the process for reassembling the pump and replacing the shaft seal after servicing.

The Shaft Seal

Describes the components and function of the shaft seal and when it might need replacement.

Section 5: Restart Instructions

Priming the Pump

Provides a step-by-step guide on how to properly prime the pump after installation or maintenance.

Section 6: Troubleshooting

Problems and Corrective Actions

Lists common pump issues and their corresponding solutions to help users diagnose and fix problems.

Section 7: Technical Data

Illustrated Parts List

Provides a visual breakdown of pump components with corresponding part numbers for easy identification and ordering.