8.3 Set the fuel cock to off. NOTE:
To stop the generator in an emergency, turn
the ignition switch to OFF.
9. MAINTENANCE
User should service the unit according to the Maintenance Schedule as follows:
Element Daily
checks
After first
month
Every 3
months
Every 6
months
Annual
Check engine oil check
Replace engine oil replace replace
Air filter check
Air filter clean
Oil drain cup clean
Spark plug clean
Fuel filter cup clean
Fuel filter clean
Valve clearance Check / adjust
Clean cylinder cover curatare
Clean fuel tank Wash it, if necessary; replace every 3 years
Check battery Before starting the generator
9.1 Replacement of engine oil
1. Turn and then take out the dipstick.
2. Unscrew the drain plug, and empty the engine oil from the crankcase.
3. Screw on the drain plug.
4. Fill engine oil to the upper level mark of the dipstick.
Engine oil recommended: 4-stroke gasoline engine oil – engine oil class SE, SF from API
Service classification or SAE 10W-30 engine equivalent to Class SG.
5. Fit the dipstick to the original position.
Ver. 3/Rev. 1; Data: 21.10.2022 44