EasyManua.ls Logo

Stairmaster 8G - LCD Maintenance Mode Parameters; LCD Maintenance Mode Settings

Stairmaster 8G
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 21
Item Min Max Default Notes
CHR PERCENT: (10-90) 10 90 70
LANG (ENG,,,,,,) N/A N/A English
Language is English (ENGL), Dutch
(DUTC), French (FREN), German (GERM),
Portuguese (PORT), Spanish (SPAN),
Swedish (SWED), Italian (ITAL) or
Katakana (KATA).
CSAFE (ON/OFF) N/A N/A ON Turns CSAFE function ON or OFF
AUTO FAN (ON/OFF) N/A N/A ON Turns AUTO FAN function ON or OFF
MODEL (STAIRCLIMBER/
STEPMLL /NTM CONFIG RQD)
N/A N/A
NTM
CONFIG
REQUIRED
Set console to STAIRCLIMBER/
STEPMILL/NTM CONFIG REQUIRED
PROGRAM STATS N/A N/A
DISPLAY TEST N/A N/A 0 Access to LCD Test function
KEYPAD TEST N/A N/A 0 Access to Keypad Test function
HEART RATE TEST N/A N/A
Access to Heart Rate System Test
function
SERIAL PORT TEST N/A N/A Access to Serial Port Test function
CSAFE TEST N/A N/A 0 Access to CSAFE Test function
FAN TEST N/A N/A 0 Access to Fan Test function
MEASUREMENTS N/A N/A
Access to Integral Measurements function
(for use by Authorized Maintenance
Technician)
LAST ERROR LIST N/A N/A
LCB COMM N/A N/A
Number of times a “LCB Communication”
condition occurred since last reset
STUCK KEY N/A N/A
Number of times a “Stuck Key” condition
occurred since last reset
BACKLIGHT 1 100 50
CONTRAST 1 100 50
SPM OVERFLOW N/A N/A
Number of times machine shut down due
to higher than expected step rate.
MAX SPM 110 140 120
KEY REPEAT ON OFF ON Turns KEY REPEAT function ON or OFF

Related product manuals