Mylar Note Check (Fujitsu bill dispenser)
(The Factory Default Setting for Mylar Note Check is “NO”).
To make a change to the Mylar Note Check feature, follow the step by step procedure outlined below.
For each machines that you want to automatically clear an overpay error, these settings must be set on
the dispenser control board
.
Note: The five-position switch and red selection button are located on the dispenser control board.
IMPORTANT: Please note the original switch settings before starting this procedure. You will need to
return the switches to this original setting to assure proper operation after making any changes. As a
convenience, you can enter these original settings in the diagram to the right by simply
marking an “X” for UP or DOWN on each switch.
1. Activate the Mylar Note Check programming mode by setting: Switch 1ON; Switch 2-OFF;
Switch 3-OFF; Switch 4-ON; Switch 5-ON
2. Press the red selection button one time.
3. Advance to the Mylar Note Check step by setting; Switch 1-ON; Switch 2-OFF; Switch 3-OFF;
Switch 4 OFF; Switch 5-OFF
4. Press the red selection button Twenty-five times.
5. Now set switches to desired setting Choice numbers 1 or 2 from the table below. Example: Set
switches to match Choice 2 if you want the Overpay Timer set to yes. Once you’ve made your
selection, press the red selection button one time.
6. End the programming sequence by resetting the switch to their original settings, and then press
the red selection button one time to put the machine back into service.
Example: When set to YES the connected Fujitsu bill dispenser will check for Mylar bills being
dispensed.
MYLAR NOTE CHECK CHOICES
CHOICE
SETTING
SWITCH POSITIONS
SW2
SW3
SW4
SW5
1
NO
UP
UP
UP
UP
2
YES
DOWN
DOWN
DOWN
UP