Display
Step Description
Index Value Status Code
7 Select Motor 2 handing 02 00 = Right hand
01 = Left hand
A0
8 Accept FIS. As soon as the VALUE is changed to 01,
display will go to INDEX 00 (Open Speed value) and then
to A1. (Note: 09 is the default value for low energy.)
03 01 A1
9 Make changes: Safety Logic
(Note: If there are no sensors connected, leave at default
value of 00.)
11 00 = Sensor
01 = Sentrex
02 = Carpet
03=Carpet 12 sec.
04= Bifold
A1
10 Function switch: Switch to OPEN, momentarily, then
CLOSED/LOCKED. Wait for the learn sequence to end.
Display will show A2
when finished.
A2
11 Lock keypad 99 01 00
12 Final Tune in
Table 2. MC521 Mode Values
Code MC521 Operational Mode
01 Dura-Glide door style—Single Motor
02 Dura-Glide door style—Dual Motor
03 Magic-Swing Door Style—Single Motor
04 Magic-Swing Door Style—Dual Motor
05 Magic-Force Door Style—Single Motor
06 Magic-Force Door Style—Dual Motor
07 Magic-Force Door Style—Single Motor Low Energy
08 Magic-Force Door Style—Dual Motor Low Energy
09 Bifold door style--Single Motor
10 Bifold door Style--Dual Motor
Table 3. Index List
Index Description
00-89 API Mode Specific Door Operational Values-These depend upon the mode selected
90-95 Reserved
96 Command - Restart FIS. Entering 01 will cause FIS to restart.
97 Reserved
98 Command – RESTART AUTOCONFIGURATION, Entering 01 will cause auto configuration.