• Apply Loctite 243 to the mating threads of the Pulling Head Adapter (76003-15003) and the Pulling Head
Extension (2).
• Attach the Pulling Head Extension (2) to the Pulling Head Adapter (76003-15003) and tighten with spa-
nners.
• Apply Loctite 243 to the mating threads of the Pulling Head Extension (2) and the Pulling Head (76003-
15002).
• Attach the Pulling Head (76003-15002) and Jaw Guide Assembly to the Pulling Head Extension (2) and
tighten with spanners.
• Place ORing (3) over the threads on the Nose Casing Extension (1).
• Place Nose Casing Extension (1) over the Pulling Head (76003-15002), Jaw Guide Assembly and Pulling
Head Extension (2) and tighten fully onto the tool.
• Place Nose Casing (76003-15001) and Nose Tip over the jaw guide and tighten fully onto the Nose Casing
Extension (1).
PREPARING THE BASE TOOL TO ACCEPT NOSE EXTENSION ASSEMBLY 76003-20300 & 71230-20300
IMPORTANT - READ THE SAFETY WARNINGS LISTED IN THE PROSET XT3 AND PROSET XT4 INSTRUCTION
MANUAL CAREFULLY BEFORE PUTTING INTO SERVICE.
IMPORTANT - THE AIR SUPPLY MUST BE TURNED OFF OR DISCONNECTED BEFORE FITTING OR
REMOVING THE SWIVEL HEAD NOSE ASSEMBLIES.
• The air supply must be disconnected.
• Remove the complete Nose Assembly (76003-15000) as described on page 9 of the Proset XT3 and Proset
XT4 instruction manual.
FITTING THE NOSE EXTENSION ASSEMBLY 76003-20300 & 71230-20300
IMPORTANT - READ THE SAFETY WARNINGS LISTED IN THE PROSET XT3 AND PROSET XT4 INSTRUCTION
MANUAL CAREFULLY BEFORE PUTTING INTO SERVICE.
IMPORTANT - THE AIR SUPPLY MUST BE TURNED OFF OR DISCONNECTED BEFORE FITTING OR
REMOVING THE NOSE EXTENSION KITS.
Refer to g. 15 and Tables 7 and 8.