TECHNICAL DATA
MODEL BOILER NON BOILER DHW
Fuel Coal Wood Coal Wood Coal Wood
Parameter
Max Heat Output (kW) 10 10 8 8 10 10
Nominal Heat Output (kW) 7.4 7 4.1 5.5 9.1 9.2
Output to Room (kW) 1.5 2.1 4.1 5.5 6.5 6.3
Output to Water (kW) 5.9 5.4 N/A N/A 2.7 3
Typical Refuel Interval To
Achieve Nominal Outputs (h)
4.15 1 4 1.5 1 0.75
Mean Flue Gas Temp. (
o
C) 264 240 250 250 245 286
Gross Weight (kg) 147 135 135
Max Water Pressure (Bar) 2 N/A 2
Flue Outlet Diameter (mm) 152 152 152
Wood Log Size (mm) N/A 300 N/A 300 N/A 300
18
Model
Energy
Efficiency
Class
Heat Output
to Room
Heat Output
to Water
Energy
Efficiency
Index
Preferred
Fuel
Nominal
Heat
Output
Net Efficiency
Tara HPB
SF Stove A 2.1 5.4 106.42 Wood 7.5 79.6
Tara NB
SF Stove
A 5.5 N/A 100.48 Wood 5.5 75.5
Tara DHW
SF Stove A 6.3 3 103.96 Wood 9.3 77.9
RECOMMENDED FUELS
All fuels should be stored under cover and kept as dry as possible prior to use.
This appliance has been tested using seasoned wood logs and manufactured briquetted smokeless fuel (Ancit)
for closed appliances, sized between 20g and 140g. Other fuels are commercially available and may give sim-
ilar results. Wood logs up to 380mm long are suitable. All fuels should be stored under cover and kept as dry
as possible prior to use.
Do not use fuels with a Petro-coke ingredient as this may cause the grate to overheat, causing damage.
Reduced outputs will result when fuels of lower calorific values are used. Never use gasoline or gasoline type
lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or freshen up a fire in this heater. Keep all
such liquid well away from the heater at all times. Operate the stove only with the fuelling door closed except
for re-fuelling.
This stove has obtained HETAS Ltd approval for burning natural and manufactured smokeless fuels only as
detailed in recommended fuels below. HETAS Approval does not cover the use of other fuels either alone or
mixed with the recommended fuels listed, nor does it cover instructions for the use of other fuels.