3.2.3. DIP Switches
DIP switches are loaded when the power is turned on or when the printer is reset. Therefore, when you change the settings,
enable them by turning the printer on again, or by executing a printer reset.Turn the power off before changing the PCB and
interface type.
DIP switch Feature ON OFF
DIPSW1 Sets IP address acquisition timeout No timeout 20 seconds (factory default setting)
DIPSW2 Reserved (Fixed at off) - -
DIPSW1
Sets the timeout time when getting the address from a DHCP/BOOTP server. The factory default setting (when set
to off) is 20 seconds.
When set to on, there is no timeout.
If this product is connected directly to an intelligent switch or intelligent hub, the physical link may take some time to
become established. As a result, a timeout will occur while waiting to get the DHCP/BOOTP address, and it will fail
to get the IP address. In such cases, set DIPSW1 = ON to have no IP address acquisition timeout.
DIPSW2
Presently unused. A feature will be added in the future. This should always be off.
3.2.4. LED
There is a red and a green LED equipped on the network interface connector (LAN connector RJ45).
These function as outlined below under normal operating conditions.
Red (LINK/Activity): A link has been established between the port and the connected device.
Communications are ready at both devices.
Green (100M): Lights when the port is operating at 100 Mbps.
Forothers,theashingpatternchangesaccordingtothepressingofthepushswitch.