RDCM V03-1015 27
7 Failures
7.1 Overview failure Messages RDEB2013
User manual Starline RoldeckUser manual Starline Roldeck
Consult the failure table below in cause of a display error.
Contact the installer if necessary.
Display Error Description
F01 • No sensor signal by start motor
F02 • No sensor signal during running for ≤ 1 second
F03 • Wrong direction of rotation (50 pulses in the wrong direction)
F04 • Short-circuit (motor current> 30A)
F05 • Too much current (motor current for 10 s> 9.5 A)
F06 • Runtime error (Roldeck> 900s, bottom lid > 120s)
F07 • Overvoltage (motor voltage for 5s> 45V)
F09 • Overtemperature chopper module (temp> 100 ° C)
F10 • Sensor short circuit (sensor inputs A & B)
F11 • Sensor error (both sensors are different)
F12 • Absolute overvoltage (motor voltage> 60V)
F21 • Water Level Sensor Input Open (RD Model: SK)
F22 • Key switch off “0”
F31 • Under pressure Roldeck driver, low pressure in in-roller motor Roldeck
F32 • Under pressure liddriver, low pressure in in-roller motor of moveable bottom flap
For error F04, F11 and F12: switch control off