74
The measured data in the individual records are based on the following units:
temperatures operation hours solar radiation power flow rate
daily values °C minutes W/m² W Liter
monthly values - hours kWh/m² Wh Liter
annual values - - kWh/m² kWh
Necessary settings for direct connection to a PC/laptop:
The required new connection must be added under “Start ÆSettings ÆControl panel Æ
Modems” or “Telephone and modem options”.
Select “Select modem (no automatic detection)”. Select “Standard modem types” as manufacturer
and, as model, “Remote network with serial cable between 2 PCs” or “Standard modem 19200 bps” or
Communication cable between 2 computers”. Check under “Settings” if the remote network is set
correctly with a “Maximum speed” of “19200” at most. Change the value accordingly if necessary.
Now the new remote network must be set under “My computerÆRemote network” or “StartÆ
Settings ÆControl panel ÆRemote network”. (If not available remote network must first be
installed under “Start ÆSettings ÆControl panel” ÆSoftware ÆWindows setup Æ
“Connections”.) Any network name can be entered for the system regulator. Under “Dial with:” the
chosen modem / cable must now be selected. The “Dial-up number” can be authorized or allocated
any chosen number if required by the system.
With “Remote networkÆ Properties the following settings must be made under “Server”:
- under Type of server “ select “SLIP
- under Network protocols” “TCP/IP” must be marked
- under TCP/IP settings...” “172.16.1.1” must be entered as the “IP address” and the points “IP
header compression...” (or “IP header ...”) and “Standard gateway...” must be deactivated.
The system regulator can now be accessed by the computer using the “Remote network”. After
successful completion of the remote network connection Microsoft Internet Explorer, for example, can
be used as operating software.
You can access the system regulator at the address “http://172.16.1.2”.
If access is not possible the following settings may have to be made, depending on the version of
Explorer:
-Internet optionsÆTemporary Internet filesÆSettingsÆ activate “With every access...”
-Internet optionsÆConnectionÆ activate “Connect via a modem”
Æ deactivate “Connect via a proxy server “
Detailed setting information with the different versions of Windows can be downloaded from the
homepage www.stecasolar.com
under “Service Thermal”.