18
Angle of coverage L 910 S: 180°
L 930 S: 140°
Time setting L 910 S, L 930 S: 120 sec. - 15 min.
Twilight setting L 910 S, L 930 S: 2 - 20lux
Effect light L910S, L930S: optionally via DIP switch
Lamp LED
IP rating IP 44
Protection class L910S, L910: II
L930S, L930: I
Ambient temperature -20°C to +40°C
Energy efficiency class L910S, L910 contain an energy class "E"
light source.
L930S, L930 contain an energy efficiency class "D" light
source.
11. Troubleshooting
Malfunction Cause Remedy
Light without power n Fuse has tripped,
not switched ON,
break in wiring
n Short circuit in mains power
supply lead
n Any mains switch OFF
n Activate, change fuse,
turn ON mains switch, check
wiring with voltage tester
n Check connections
n Switch on mains switch
Light does not switch ON n Wrong twilight setting selected
n Mains switch OFF
n Fuse has tripped
n Reset
n Switch ON
n Activate, change fuse,
check connection if necessary
Light does not switch OFF n Continued movement within
the detection zone
n Check detection zone
Light does not switch OFF
completely
n Basic light level selected n Check DIP 1 and DIP 2
Light switching ON
despite no movement
being detected
n Light not mounted for
detecting movement reliably
n Movement occurred but not
identified by the observer
(movement behind wall, small
object moving in immediate
proximity of lamp etc.)
n Securely mount enclosure
n Check detection zone