1. Calculate the Available Dose Time in Seconds.
The available dose time is the minimum time interval between the water meter
contact closures.
a.
60 Seconds
= Maximum System Flow Rate (spg)
Maximum System Flow Rate (gpm)
b.
Maximum System Flow Rate (spg)
Water Meter’s contacts per gallon (cpg)
*
= Available Dose Time (sec.)
*
Refer to the water meter model to confirm the contact rate (cpg).
2. Calculate the Pump Operating Time in Seconds.
Pump Output Requirement (gpd) x Available Dose Time (sec.)
=
Pump Operating
Pump’s Maximum Output (gpd)
Time (sec.)
PUMP OPERATING TIME EXCEEDING AVAILABLE DOSE
TIME MAY LEAD TO DOSING ERRORS. To reduce operating time, select a pump with
a higher output or use a stronger solution strength.
3. Calculate the Pump Operating Time Percentage.
Reference the chart to find the pump’s maximum operating time for the formula below.
Pump Operating Time (sec.)
x 100 =
Pump Operating Time Percentage
Maximum Pump Operating Time (sec.)
**
**
Value can only be 1, 5, 10, 20, or 60.
Seconds Mode
MAXIMUM Pump Operating
Time in Seconds
1 SECOND 1.0
5 SECONDS 5.0
10 SECONDS 10.0
20 SECONDS 20.0
60 SECONDS 60.0
PROGRAM PUMP SETTINGS
SECONDS MODE (dry contact signal)