ENGLISH
105
17.5 Pressure drop
Taps/valves
Mono lever mixer tap, approx. MPa 0.04 - 0.08
Thermostatic valve, approx. MPa 0.03 - 0.05
Shower head, approx. MPa 0.03 - 0.15
Sizing the pipework
When calculating the size of the pipework, an appliance pressure
drop of 0.1MPa is recommended.
17.6 Fault conditions
In the event of a fault, loads up to 80 °C at a pressure of 1.0 MPa
can occur briefly in the installation.
17.7 Test symbols
See type plate on the appliance.
17.8 Details on energy consumption
The product data complies with EU regulations relating to the
Directive on the ecodesign of energy related products (ErP).
234467 234468 234459 234460
Manufacturer STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON
Load profile S S S S
Energy efficiency class A A A A
Annual power consumption kWh 479 473 479 473
Energy conversion efficiency % 39 39 39 39
Default temperature setting °C 60 60 60 60
Sound power level dB(A) 15 15 15 15
Special information on measuring effi-
ciency
Data at Pmax. Measured with flow limita-
tion to 9 l/min
Data at Pmax. Measured with flow limita-
tion to 9 l/min