Fit a suitable pressure tap.
Push the lower back panel section under the connecting
pipes of the tap and push it into the back panel.
Secure the connection pipes to the tee and the 3-way ball
shut-off valve.
Note
You can break off the pipe fitting tabs on the lower back
panel section if required.
D0000056194
1
1 Tab
13.7 Water installation on finished walls with
solder/compression fittings
You can connect copper or plastic pipes using the accessories
"solder fitting" or "press-fit fitting".
With "solder fitting" with threaded connection for 12 mm copper
pipes, proceed as follows:
Push the union nuts over the connection pipes.
Solder the inserts to the copper pipes.
Push the lower back panel section under the connecting
pipes of the tap and push it into the back panel.
Secure the connection pipes to the tee and the 3-way ball
shut-off valve.
Note
Observe the tap manufacturer's instructions.
13.8 Fitting appliance cover over water installation
on finished walls
D0000053285
4
3
2
1
1 Back panel guides
2 Screw
3 Cover guide pieces with sealing lips on the pipe side
4 Pipe knock-outs
Cleanly saw and break out the pipe knock-outs in the appli-