www.stiebel-eltron.com DHM 6 220 | 17
INSTALLATION
SPECIFICATION
15.5 Data table
DHM 6 220
220815
Electrical details
Rated voltage V 220
Rated output kW 6,0
Rated current A 27,3
Fuses A 32
Frequency 2 Hz 50
Phases 1/N/PE
Specific resistance ρ
15
≥ (at ϑcold ≤25 °C) Ω cm 1100
Specific conductivity σ
15
≤ (at ϑcold ≤25°C) μS/cm 909
Specific resistance ρ
15
≥ (at ϑcold >25°C) Ω cm 1100
Specific conductivity σ
15
≤ (at ϑcold >25°C) μS/cm 909
Max. mains impedance at 220V / 50Hz Ω 0,358
Connections
Water connection G 3/8 A
Values
Max. permissible inlet temperature °C 35
ON l/min > 2,6
Pressure drop at flow rate MPa 0,09
Flow rate for pressure drop l/min 2,6
DHW delivery l/min 3,4
Δϑ at DHW delivery K 25
Hydraulic data
Rated capacity l 0,1
Versions
Oversink installation X
Undersink installation X
DHM 6 220
Open vented type X
Sealed unvented type X
Protection class 1
Insulation block Plastic
Heating system heat generator Bare wire
Cap and back panel Plastic
Colour white
IP-Rating IP25
Energy data
Energy efficiency class A
Dimensions
Height mm 143
Width mm 190
Depth mm 82
Weights
Weight kg 1,4