Installation
Mark out the holes to be drilled, see chapter "Installation/
Specification/ Dimensions and connections".
Drill the holes and secure the wall mounting bracket with
2screws and 2rawl plugs (screws and rawl plugs are not
part of the standard delivery).
Mount the wall mounting bracket.
160
≥ 30
26�02�02�0887
Prepare the power cable.
Preparing the water connection
!
Material losses
Carry out all water connection and installation work in
accordance with regulations.
D0000041720
Remove the caps from the tees.
Fit the plugs and the extensions with gaskets.
D0000041721
Fit the strainer in the tee for the cold water inlet.
!
Damage to the appliance and environment
The strainer must be fitted for the appliance to function.
When replacing the appliance, check that the strain-
er is present.
D0000041722
12
1 Flow limiter
2 Plastic profile washer
Fit the flow limiter or the plastic profile washer.
Note
Install the flow limiter.
With low water pressure, the pressure drop can be
reduced by replacing the flow limiter with the plastic
profile washer provided.
Installing the appliance
26�02�02�1336
For easy installation, push the cable grommet of the upper
electrical connection into the back panel from behind.
Remove the transport plugs from the water connections.
Remove the fixing toggle from the upper part of the back
panel.
Route the power cable through the cable grommet from be-
hind, until the power cable rests against the cable sheath.
Align the power cable.
If the cross-section is >6mm², enlarge the hole in the cable
grommet.
Push the appliance over the threaded stud of the wall mount-
ing bracket, so that it breaks through the soft seal. If neces-
sary, use a screwdriver.
Push the fixing toggle on to the threaded stud of the wall
mounting bracket.
Push the back panel firmly against the wall. Lock the fixing
toggle by turning it 90° clockwise.